10 Tips for Successful Sample Concentration and Buffer Exchange

Featured In: Bioscience Technology Magazine | Filters | Filtration Apparatus

By Lisa Morrill and Sandrine Mercier, Millipore Corp. Friday, November 6, 2009

newsvine diigo google
slashdot
Share
Loading...

Centrifugal devices with ultrafiltration (UF) membrane can solve common problems researchers face when working with proteins.

You’ve finally purified all the protein you need to study its structure, function, and thermal stability. Unfortunately, the protein is in a solution that you can’t use. It’s too dilute, in too large of a volume, and the buffer contains so much salt and detergent that it will adversely affect protein function or kill any cells that come near it.
Centrifugal devices with ultrafiltration (UF) membrane can solve all of these problems for proteins, nucleic acids, virus preps, and more. Harness the power of ultrafiltration membranes to separate and concentrate dissolved macromolecules, and you can prepare samples that provide reproducible, accurate data for any downstream analysis.

 
  Particle size dictates what type of membrane-based sample preparation tool should be used  
click to enlarge 
Figure 1: Particle size dictates what type of membrane-based sample preparation tool should be used. (All images courtesy: Millipore Corp.)

Why should I use UF instead of dialysis or lyophilization?
UF is far gentler to solutes than non-membrane-based processes such as precipitation or lyophilization. It is easier, faster, and higher yielding than dialysis. UF is more efficient because it can simultaneously concentrate and desalt solutes. There is no phase change, which often denatures labile species, and you can perform UF at room temperature or in a cold room or refrigerated centrifuge.
Follow these tips to enhance your research with ultrafiltration.

#1 Make sure UF is the right tool for your sample.
There are many types of membrane-based sample preparation tools out there. Which one should you use? The answer depends on the size of your molecule (figure 1).

 
  A typical centrifugal ultrafilter  
click to enlarge 
 
Figure 2: A typical centrifugal ultrafilter.

#2 Choose the right UF device for your sample.
First, select the device based on starting volume, final volume or desired concentration factor (figure 2). Centrifugal filters come in a variety of sizes, accommodating samples between 0.5 mL and 15 mL. Final volumes can vary between 15 µL and 200 µL, and concentration factors are generally between 30× and 75×.
Second, choose the membrane with an appropriate nominal molecular weight limit (NMWL), which is equivalent to the molecular weight cutoff (MWCO). You’ll get the best results with a membrane with MWCO that is 2× smaller than the molecule you wish to retain. If you have the choice between two cutoffs, pick the smaller one to start.
For most single-stranded and double-stranded nucleic acids, cutoffs between 30,000 to 100,000 give the best recoveries.

#3 Make sure your sample is chemically compatible with the centrifugal filter.
Centrifugal ultrafilters can withstand a certain pH range and a certain percentage of organic solvent. Outside of these ranges, the filter can crack, leak, or become otherwise compromised, resulting in sample loss or sample contamination.
Read the manufacturer’s recommendations provided with the filter to make sure the chemical composition of the sample doesn’t affect the filter’s performance.

 
 Concentration polarization working against you 
click to enlarge 
Figure 3: Concentration polarization working against you: Buildup of solutes (blue) on the membrane prevents impurities (yellow) from passing.
#4 Avoid concentration polarization.
Concentration polarization refers to a buildup of solutes on the surface of the membrane. This prevents low molecular weight solutes from passing through the pores as they would normally do, resulting in inefficient sample concentration or desalting (figure 3).
Steps you can take to prevent concentration polarization:
• Dilute highly concentrated samples.
• Use a centrifugal filter with a vertical membrane.
• Spin at a lower speed.

#5 Actually, four tips to speed up the UF process:
• Use a filter with a vertical membrane to prevent concentration polarization.
• Choose the highest possible MWCO—up to half the molecular weight of the retained molecule.
• Remove large particles from (pre-clarify) the sample by syringe microfiltration or centrifugal microfiltration.
• Read the filter manufacturer’s guidelines to decide exactly how long to centrifuge your sample and whether dividing the time into multiple centrifugation steps can speed up the concentration process.

#6 Keep your molecule biologically active for best assay results.
UF is conducive to preserving biological activity of solutes, because it does not typically change the salt concentration of the solution. However, you should:
• Avoid spinning to dryness. Using a filter with a dead stop enables concentration in a single spin and concentration of multiple samples in parallel without calibrating spin times.
• Ensure that the molecule is soluble at the final concentration.
• Use a refrigerated centrifuge for temperature-sensitive molecules.
• When concentrating viruses, test activity at various titers and stop concentrating further when activity shows any signs of diminishing.

 
  Use inverted spin for consistent recovery of low volume samples  
click to enlarge 
 
Figure 4: Use inverted spin for consistent recovery of low volume samples with minimal pipetting errors.
#7 Maximize recovery of your molecule of interest—recover 90% of your sample or more.
• Use a membrane with an appropriate MWCO.
• Use a centrifugal filter with a vertical membrane.
• Choose a low-binding membrane to minimize nonspecific binding of solutes (e.g., regenerated cellulose acetate membrane with polypropylene housing).
• Use a reliable centrifugal filter that has been validated to function without leakage or breakage. See Tip #2 for advice on chemical compatibility.
• Choose the correct rotor and centrifugation speed for the filter by following the manufacturer’s directions. The wrong choices here could also structurally compromise the filter, causing lost sample.
• Avoid spinning to dryness. For peace of mind, use a filter with a dead stop (volume past which sample cannot be further concentrated).
• For consistent recovery of low volume samples with minimal pipetting errors, invert the device after concentration and spin again into a new collection tube (see figure 4).

 
  /uploadedImages/BST/Application_Notes/2009/10/Millipore-Fig.5.jpg  
click to enlarge 
 
Figure 5: How to use a centrifugal filter to concentrate a protein 10× while also gradually reducing the salt concentration by 9×.
#8 Use gradual desalting for sensitive macromolecules.
Because some macromolecules can lose activity or proper structure upon extreme changes of buffer conditions, change buffer conditions gradually or use diafiltration. Diafiltration involves removing microsolutes by adding solvent to the sample being filtered at the same time that ultrafiltration is being applied.
Figure 5 shows an example of how you can use a centrifugal filter to concentrate a protein 10× while also gradually reducing the salt concentration by 9×.

#9 Dilute samples with concentrated detergents in the buffer.
Dilute the sample so the detergent concentration is low enough that micelles (large, organized detergent aggregates) do not form. If the sample contains micelles, UF will concentrate the detergent even further. Different detergents have different critical micelle concentrations.

#10 Tell all your colleagues about the ease and effectiveness of UF.
The more people around you that use UF, the more tips you can share on optimizing UF. Here’s a partial list of UF applications:
• Protein applications, including concentration and buffer exchange
• Concentrating chromatography fractions
• Concentration antibodies
• Desalting any protein sample, instead of dialysis
• Removing detergents
• Nucleic acids
• PCR clean-up and primer removal, purification of DNA sequencing reactions
• Genomic DNA concentration and desalting
• Clinical applications
• Deproteination of clinical samples for drug discovery & development
• Concentration of biological samples (urine, cerebrospinal fluid, blood) for analysis
• Measuring the levels of unbound drugs, heavy metals, or other soluble molecules (such as hormones used for doping)
• Separating free from bound metabolites in serum samples
• Viruses used for gene transduction
• Concentration by UF is efficient, but it is difficult to separate soluble proteins from viruses in cell culture media by UF. Use UF to concentrate and desalt virus preparations only.

What’s next?
Now that you have your native, folded, active molecule in a usable volume and concentration, your next assay will more likely be a published figure, instead of a “Troubleshooting” slide in your next group meeting presentation.

About the Authors
Lisa Morrill leads the direction of technology development at Millipore including sample concentration, purification, and immunodetection portfolios.
Sandrine Mercier integrates development and marketing for the Amicon Ultra centrifugal filters at Millipore.

This article was published in Bioscience Technology magazine: Vol. 32, No. 10, October, 2009, pp. 14-19.

Join the Discussion
Rate Article:  Average 0 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

Microplate Reader Test Plates Ensure Reliable Microplate Reader Operation

Aug 20

Use of a certified test plate can help to increase efficiency when calibrating microplate readers.

Automated Imaging Assisted Cell Line Development

Aug 19

Improve titer, quality and speed in cell line development.

New Frontiers: The Changing World of Biospecimen Collection and Management

Jul 30

The growth of biomarker research and personalized medicine requires more unified and large-scale software systems to track biological materials.

Optical Imaging in Stem Cell Research

Jun 1

Developing sensitive, non-invasive technologies to monitor engraftment in vivo is essential to accelerate the clinical implementation of cell therapies.

Step up to the MIQE

Mar 30

Over the years, polymerase chain reaction (PCR) has evolved into a readily automated, high throughput quantitative technology. Real-time quantitative PCR (qPCR) has become the industry standard for the detection and quantification of nucleic acids for multiple application, including quantification of RNA levels. But a lack of consensus among researchers on how to best perform and interpret qPCR experiments presents a major hurdle for advancement of the technology. This problem is exacerbated by insufficient experimental detail in published work, which impedes the ability of others to accurately evaluate or replicate reported results.

Fast Optimization of a Multiplex Influenza Identification Panel Using a Thermal Gradient

Mar 30

The year 2009 was marked by the emergence of a novel influenza A (H1N1) virus that infects humans. There is a need to identify the different strains of influenza virus for purposes of monitoring the H1N1 strain pandemic and for other epidemiological and scientific purposes.

Advantages of Monolithic Laser Combiner Technology in Confocal Microscopy Systems

Jan 6

Fluorescence microscopy techniques require a reliable light source at the desired wavelength or wavelengths, with minimal downtime for maintenance and alignment. Lasers are a popular light source, although the alignment and upkeep of laser combiners is a time-consuming prospect for many users.

Size-Exclusion Chromatography for Purification of Biomolecules

Dec 2 2009

Size-exclusion chromatography (SEC) is a popular method to separate biomolecules based on their size. Primarily, it is applied to the separation of biopolymers such as proteins and nucleic acids, i.e. water-soluble polymers.

Using the Tecan Genesis Workstation to Automate a Cytometric Bead Array (CBA) Immunoassay

Mar 11

The poster describe the process involved in automating a Cytometric Bead Array (CBA) immunoassay developed to measure relative concentrations of serum antibodies against Tetanus (TT), Sperm Whale Myoglobin (SWM) and Keyhole Limpet Hemocyanin (KLH) in KLH-immunized volunteers.

Ensuring Quality in Assays Performed with Automated Liquid Handlers

Feb 2

The focus of this presentation is to highlight the need of ensuring quality in important assays performed with automated liquid handlers. Nearly all assays performed within a laboratory are volume-dependent. In turn, all concentrations of biological and chemical components in these assays, as well as the associated dilution protocols, are volume-dependent. Because analyte concentration is volume-dependent, an assay’s results might be falsely interpreted if liquid handler variability and inaccuracies are unknown or if the system(s) go unchecked for a long period.

Inkjet System for Protein Crystallography

Feb 1

X-ray crystallography is used routinely by scientists to obtain the three dimensional structure of a biological molecule of interest.Such information can be used to determine how a pharmaceutical interacts with a protein target and what changes might improve functionality. However, the crystallization of macromolecules still remains a serious hindrance in structural determination despite impressive advances in screening methods and technologies.

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Nov 9 2009

Action selection is modulated by external stimuli either directly or via memory retrieval. In a constantly changing environment, animals have evolved attention-like processes to effectively filter the incoming sensory stream. These attention-like processes, in turn, are modulated by memory. The neurobiological nature of how attention, action selection and memory are inter-connected is unknown. We describe here new phenotypes of the memory mutant radish in the fruit fly Drosophila.

Efficient Bayesian approach for multilocus association mapping including gene-gene interactions.

1 hour ago

ABSTRACT: BACKGROUND: Since the introduction of large-scale genotyping methods that can be utilized in genome-wide association (GWA) studies for deciphering complex diseases, statistical genetics has been posed with a tremendous challenge of how to most...

Influenza A/pandemic 2009/H1N1 in the setting of allogeneic hematopoietic cell transplantation: a potentially catastrophic problem in a vulnerable population.

2 hours ago

We describe Influenza A/pandemic 2009/H1N1 in two allogeneic hematopoietic cell transplantation recipients. The main presentation in both cases consisted of flu-like symptoms manifesting as, fever, arthralgias and myalgias. The virus was isolated in one case...

Outcomes of matched sibling and alternative donor stem cell transplantation for 26 children with severe aplastic anemia.

2 hours ago

In this study, we reported the outcomes of hematopoietic stem cell transplantation (HSCT) as a treatment modality for pediatric patients admitted over the past 20 years in a single institute. From January 1989 to January 2007, 26 patients with a median age of 8...

Structural Interpretation in Composite Systems Using Powder X-ray Diffraction: Applications of Error Propagation to the Pair Distribution Function.

2 hours ago

PURPOSE: To develop a method for drawing statistical inferences from differences between multiple experimental pair distribution function (PDF) transforms of powder X-ray diffraction (PXRD) data. METHODS: The appropriate treatment of initial PXRD error estimates...

Prokariotic Cell Collection in Denmark

Nov 6 2009

I would like to know about a prokariotic cell collection in Denmark. Is there a cell bank in this country? I need a Lactobacillus strain for a fermentation assay and this information about the bank is very helpful for me.

Request for Entries

Oct 16 2009

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.          

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   

MULTIMEDIA

Video:

Viewing SureFocus Slides

Jun 11

A demonstration of SureFocus Microscope Slides in the review of AFB Smears. SureFocus Slides are a patent-pending breakthrough in tuberculosis detection, as their fluorescent staining circle remains visible during review, Fluorescence Microscopy.

Podcasts:

Allen Institute for Brain Research

Allen Institute for Brain Research

Oct 14 2009

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.